Economy Muffle Furnace up to 1100 °C
Laboratory Furnace With Fast Heating
Laboratory Furnace With Fast Heating
Laboratory Furnace With Fast Heating
Model No. :
Brand : Nabertherm
The LE series serves as a highly economical choice for various laboratory heating applications requiring temperatures up to 1100 °C. These units feature heating elements integrated into vacuum-formed fiber modules to ensure efficient thermal distribution and a lightweight construction.
-
Two sided heating from both sides
-
Vacuum formed fiber insulation for efficiency
-
Dual shell housing ensures low temperatures
− Features
- Tmax 1100 °C
- Heating from two sides from heating elements protected in quartz glass tubes Fast heating times (see table)
- Maintenance-friendly replacement of heating elements and insulation
- Housing coated in RAL 9003
- Solid state relays provide for lownoise operation
- Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
- Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
- Flap door which can also be used as a work platform
- Exhaust air outlet in rear wall
- Compact dimensions and light weight
- Controller mounted under the door to save space
- Controller R8 (adjustable for one temperature)
- Defined application within the constraints of the operating instructions
+ Technical Specifications
| Model | LE 1/11 | LE 2/11 | LE 6/11 | LE 14/11 | LE 24/11 | |
| Tmax | in°C1 | 1,100 | 1,100 | 1,100 | 1,100 | 1,100 |
| Inner dimensions in mm | w | 90 | 110 | 170 | 220 | 260 |
| Inner dimensions in mm | d | 115 | 180 | 200 | 300 | 330 |
| Inner dimensions in mm | h | 110 | 110 | 170 | 220 | 280 |
| Volume | in l | 1 | 2 | 6 | 14 | 24 |
| Outer dimensions2 in mm | w | 290 | 330 | 390 | 440 | 490 |
| Outer dimensions2 in mm | d | 280 | 390 | 440 | 540 | 570 |
| Outer dimensions2 in mm | h | 410 | 410 | 470 | 520 | 590 |
| Temperature uniformity of +/− 5K in the empty workspace4 | w | 40 | 60 | 120 | 170 | 200 |
| Temperature uniformity of +/− 5K in the empty workspace4 | d | 65 | 130 | 150 | 250 | 270 |
| Temperature uniformity of +/− 5K in the empty workspace4 | h | 60 | 60 | 120 | 170 | 230 |
| Connected load5 | in kW | 2 | 1.9 | 2 | 3.2 | 3.5 |
| Electrical | connection | 1-phase | 1-phase | 1-phase | 1-phase | 1-phase |
| Weight | in kg | 15 | 20 | 27 | 35.00 | 42.00 |
| Heating time | in min3 | 10 | 15 | 30 | 35 | 40 |
1Recommended working temperature for processes with longer dwell times is 1050 °C
2External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.
3Heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE)
4Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C see page 77
5The connected load refers to the standard furnace and may increase for a furnace with additional equipment. For furnaces with connection options for multi-range voltages, the connected load applies to the highest permissible connected voltage.
+ Resources
Features
- Tmax 1100 °C
- Heating from two sides from heating elements protected in quartz glass tubes Fast heating times (see table)
- Maintenance-friendly replacement of heating elements and insulation
- Housing coated in RAL 9003
- Solid state relays provide for lownoise operation
- Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
- Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
- Flap door which can also be used as a work platform
- Exhaust air outlet in rear wall
- Compact dimensions and light weight
- Controller mounted under the door to save space
- Controller R8 (adjustable for one temperature)
- Defined application within the constraints of the operating instructions
Technical Specifications
| Model | LE 1/11 | LE 2/11 | LE 6/11 | LE 14/11 | LE 24/11 | |
| Tmax | in°C1 | 1,100 | 1,100 | 1,100 | 1,100 | 1,100 |
| Inner dimensions in mm | w | 90 | 110 | 170 | 220 | 260 |
| Inner dimensions in mm | d | 115 | 180 | 200 | 300 | 330 |
| Inner dimensions in mm | h | 110 | 110 | 170 | 220 | 280 |
| Volume | in l | 1 | 2 | 6 | 14 | 24 |
| Outer dimensions2 in mm | w | 290 | 330 | 390 | 440 | 490 |
| Outer dimensions2 in mm | d | 280 | 390 | 440 | 540 | 570 |
| Outer dimensions2 in mm | h | 410 | 410 | 470 | 520 | 590 |
| Temperature uniformity of +/− 5K in the empty workspace4 | w | 40 | 60 | 120 | 170 | 200 |
| Temperature uniformity of +/− 5K in the empty workspace4 | d | 65 | 130 | 150 | 250 | 270 |
| Temperature uniformity of +/− 5K in the empty workspace4 | h | 60 | 60 | 120 | 170 | 230 |
| Connected load5 | in kW | 2 | 1.9 | 2 | 3.2 | 3.5 |
| Electrical | connection | 1-phase | 1-phase | 1-phase | 1-phase | 1-phase |
| Weight | in kg | 15 | 20 | 27 | 35.00 | 42.00 |
| Heating time | in min3 | 10 | 15 | 30 | 35 | 40 |
1Recommended working temperature for processes with longer dwell times is 1050 °C
2External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.
3Heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE)
4Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C see page 77
5The connected load refers to the standard furnace and may increase for a furnace with additional equipment. For furnaces with connection options for multi-range voltages, the connected load applies to the highest permissible connected voltage.
Application & Standards
Accessories
Software
FAQs
Related Products
Advancing research and development through reliable, high-quality scientific instruments tailored to your needs.