Gelnorm PVN-1
Rotating Measurement Device For Gel Time & Viscosity
Rotating Measurement Device For Gel Time & Viscosity
Rotating Measurement Device For Gel Time & Viscosity
Model No. :
PVN-1
Model No. : PVN-1
Brand : Gel Instrument
The Gelnorm PVN-1 is a precision analytical system designed to monitor the complete curing profile and sliding value of reactive resin mixtures. It provides a standardized method for evaluating the chemical reaction progress of polymers by measuring the force required to move a plunger through the curing material.
-
Continuous monitoring of resin reaction curves
-
Accurate determination of material sliding values
-
Digital recording of polymer hardening phases
[acf_all_fields_accordion]
− Features
- Rotating measurement with 1 Hz
- Control unit with USB connection
- PC software for configuration and measurement
- Sample temperature measurement
- Optional electrical heating samples
- Force measurement and idle calibrated
- Compact design, easy operatio
+ Technical Specifications
Electrical Specifications
| Power supply | 115VAC / 230 VAC , 50/ 60 Hz (with changeover switch) |
| Power consumption | 20 W, 650 W (with heating) |
| Connector | 8 pin , N, P, PE and Pt100 2 wires, plug type Binder |
| Main switch | on the rear panel |
| Fuses | 2 pieces, F 3.15A L 250 VAC |
| Electrical conformity | EMV 2014/30/EU, EN 61010-1:2010, EN 61010-2-010:2014, EN 61326-1:2013 |
| Interface | USB 2.0 type A connector |
| Motor power connection | M12 8 pin, 24 VDC, 10 W |
Temperature control for the electrical heating block GT
| Actual value (Pt100) | Range: 0.0 °C … 250.0 °C , adjustable and calibrated |
| Accuracy | ± 0.3 % of full scale ± 1 digit |
| Value, pre set | Range: 0.0 °C … 200.0 °C (on request 250.0 °C) |
| Resolution | 0.1 K |
| Load output | power max. – Resistive load: maximum 600 W self-optimization |
Temperature measurement for the sample
| Sensor | Thermocouple Type K (Ni- CrNi), EN 60 584 |
| Connector | Mini connector type K thermocouples, EN 60 584 |
| Range | 0.0 °C to 400.0 °C |
| Accuracy | ± 1.5 °C including cold-junction compensation Can be adjusted and calibrated |
+ Standards
ISO
2535
EN
2535
DIN
2535
+ Resources
Features
- Rotating measurement with 1 Hz
- Control unit with USB connection
- PC software for configuration and measurement
- Sample temperature measurement
- Optional electrical heating samples
- Force measurement and idle calibrated
- Compact design, easy operatio
Technical Specifications
Electrical Specifications
| Power supply | 115VAC / 230 VAC , 50/ 60 Hz (with changeover switch) |
| Power consumption | 20 W, 650 W (with heating) |
| Connector | 8 pin , N, P, PE and Pt100 2 wires, plug type Binder |
| Main switch | on the rear panel |
| Fuses | 2 pieces, F 3.15A L 250 VAC |
| Electrical conformity | EMV 2014/30/EU, EN 61010-1:2010, EN 61010-2-010:2014, EN 61326-1:2013 |
| Interface | USB 2.0 type A connector |
| Motor power connection | M12 8 pin, 24 VDC, 10 W |
Temperature control for the electrical heating block GT
| Actual value (Pt100) | Range: 0.0 °C … 250.0 °C , adjustable and calibrated |
| Accuracy | ± 0.3 % of full scale ± 1 digit |
| Value, pre set | Range: 0.0 °C … 200.0 °C (on request 250.0 °C) |
| Resolution | 0.1 K |
| Load output | power max. – Resistive load: maximum 600 W self-optimization |
Temperature measurement for the sample
| Sensor | Thermocouple Type K (Ni- CrNi), EN 60 584 |
| Connector | Mini connector type K thermocouples, EN 60 584 |
| Range | 0.0 °C to 400.0 °C |
| Accuracy | ± 1.5 °C including cold-junction compensation Can be adjusted and calibrated |
Application & Standards
Accessories
Software
FAQs
Related Products
Advancing research and development through reliable, high-quality scientific instruments tailored to your needs.