PTD 100 Cone-Plate

Converts Rotational Viscometer To A Cone-Plate System

Converts Rotational Viscometer To A Cone-Plate System

Converts Rotational Viscometer To A Cone-Plate System

Model No. :

PTD 100

Model No. : PTD 100

Brand : Anton Paar

The PTD 100 Cone-Plate is a premium, dual-function accessory that instantly transforms the standard ViscoQC 100 or 300 rotational viscometer into a sophisticated cone-plate system. It is uniquely suited for precise viscosity determination of materials where sample volume is limited (down to 0.5 mL) and where highly accurate temperature control is mandatory for optimal testing.

  • Combined temperature control and measurement.
  • Automated gap setting ensures reliable results.
  • Excellent repeatability using minimal sample volume.

[acf_all_fields_accordion]

− Features

  • Small-Volume Viscometry: Enables highly accurate absolute viscosity measurements using minute sample sizes, requiring only 0.5 mL up to 2.0 mL—ideal for rare, expensive, or limited-quantity materials in R&D and QC.
  • Integrated Peltier Temperature Control: Features a built-in Peltier element to precisely control the sample temperature from 0 °C to 100 °C. This eliminates the cost, maintenance, and space footprint of external fluid baths.
  • Automated Electronic Gap Setting: Automatically sets the precise, critical gap distance between the cone and the plate. This unique feature removes manual operator handling, preventing measurement inaccuracy due to improper mechanical setup.
  • Toolmaster™ Cone Recognition: Equipped with magnetic coupling and the Toolmaster™ feature, the system achieves fast cone changes (saving up to 25 seconds) while electronically detecting and logging the cone type, eliminating operator data entry errors.
  • Unified Operational Control: The entire system, including temperature setting, monitoring (via embedded Pt100 probe), and test execution, is conveniently managed via the ViscoQC’s intuitive user interface, ensuring a seamless operational experience.

+ Technical Specifications

+ Standards

+ Videos

+ FAQs

Features
  • Small-Volume Viscometry: Enables highly accurate absolute viscosity measurements using minute sample sizes, requiring only 0.5 mL up to 2.0 mL—ideal for rare, expensive, or limited-quantity materials in R&D and QC.
  • Integrated Peltier Temperature Control: Features a built-in Peltier element to precisely control the sample temperature from 0 °C to 100 °C. This eliminates the cost, maintenance, and space footprint of external fluid baths.
  • Automated Electronic Gap Setting: Automatically sets the precise, critical gap distance between the cone and the plate. This unique feature removes manual operator handling, preventing measurement inaccuracy due to improper mechanical setup.
  • Toolmaster™ Cone Recognition: Equipped with magnetic coupling and the Toolmaster™ feature, the system achieves fast cone changes (saving up to 25 seconds) while electronically detecting and logging the cone type, eliminating operator data entry errors.
  • Unified Operational Control: The entire system, including temperature setting, monitoring (via embedded Pt100 probe), and test execution, is conveniently managed via the ViscoQC’s intuitive user interface, ensuring a seamless operational experience.
Spindle Volume [mL] Shear ratea [s-1] ViscoQC 100L (Viscosity range) ViscoQC 100R (Viscosity range) ViscoQC 100H (Viscosity range) ViscoQC 300L (Viscosity range) ViscoQC 300R (Viscosity range) ViscoQC 300H (Viscosity range)
CP40 0.5 mL 7.50 * N 0.2 to 3 K 1.6 to 33.1 K 13.2 to 264.8 K 0.1 to 31 K 1.3 to 331 K 10.6 to 2.6 M
CP41 2.0 mL 2.00 * N 0.6 to 11.6 K 6.2 to 123.9 K 50 to 991.1 K 0.5 to 116.1 K 5 to 1.2 M 40 to 9.9 M
CP42 1.0 mL 3.84 * N 0.3 to 6 K 3.2 to 64.7 K 26 to 517.6 K 0.2 to 60.6 K 2.6 to 647 K 21 to 5.1 M
CP51 0.5 mL 3.84 * N 2.4 to 48.5 K 26 to 517.7 K 207 to 4.1 M 1.9 to 485.2 K 21 to 5.1 M 166 to 41.4 M
CP52 0.5 mL 2.00 * N 4.6 to 92.8 K 50 to 991.1 K 396 to 7.9 M 3.7 to 928.9 K 40 to 9.9 M 317 to 79.2 M

What is the main advantage of the integrated Peltier system?

The main advantage is that it provides fast, precise temperature control across a wide range (0 °C to 100 °C) without the need for a bulky, high-maintenance external circulating water bath and messy thermostat fluid.

What is the minimum sample volume required for testing with this system?

The PTD 100 Cone-Plate is a small-volume viscometer, capable of achieving accurate measurements with sample volumes as low as 0.5 mL (depending on the specific cone used).

How does the automated gap setting improve result reliability?

Gap setting is a critical source of error in cone-plate viscometry. The automated electronic process removes manual intervention, ensuring the gap is set precisely and monitored continuously, which guarantees superior measurement repeatability and accuracy.

Which ViscoQC models is the PTD 100 Cone-Plate accessory compatible with?

This cone-plate accessory is fully compatible with all models in the ViscoQC series, including the entry-level ViscoQC 100 (L, R, H) and the advanced ViscoQC 300 (L, R, H).

Does using the PTD 100 Cone-Plate restrict the viscosity range of the instrument?

While it changes the measurable range compared to standard spindles, the PTD 100 expands the instrument’s capability, allowing it to accurately measure low to high viscosities across all ViscoQC torque models, specifically optimized for the high shear rates inherent to cone-plate geometry.