TCT-1 | B-time
Determination Of Reactivity & B-State Time
Determination Of Reactivity & B-State Time
Determination Of Reactivity & B-State Time
Model No. :
Brand : Gel Instrument
The TCT-1 | B-time system is a precision instrument designed for the determination of B-time in heat-hardening resins according to international standards. It combines a specialized heating plate with a digital controller to identify the exact reaction point where solid or liquid resins transition into the B-stage.
-
Precise thermal control for resin testing
-
Standardized B-time evaluation for quality assurance
-
Integrated stopwatch for accurate reaction timing
[acf_all_fields_accordion]
− Features
- B-Timing Plate Design: The standard heating surface includes four specialized depressions to accept multiple samples simultaneously, with custom flat-plate versions available for specific application needs.
- Advanced Temperature Regulation: Equipped with the TCT-1 controller and a high-accuracy Pt100 sensor, maintaining a temperature range of 30°C to 200°C (expandable to 250°C) with ±0.5°C precision.
- Compliance with Standards: Specifically engineered to meet the testing requirements of DIN 16 916 and DIN EN ISO 8987, ensuring results are globally recognized for resin reactivity analysis.
- Dual-Sensor Monitoring: Features an additional Type K thermocouple connection dedicated to monitoring surface temperature, providing redundant verification of thermal stability during testing.
- Integrated Process Timer: The control unit houses a built-in digital stopwatch, allowing laboratory technicians to synchronize thermal application with precise time measurement for repeatable data collection.
+ Technical Specifications
B-Timing Plate
| Voltage | 115 VAC or 230 VAC, 50/60 Hz |
| Power | 160 W |
Temperature-Controller TCT-1 with Stopwatch
| Voltage | 100 …240 VAC, 50 / 60 Hz |
| Power | 200 VA with connected B-Timing plate |
| Connections | 8 Pol Binder plug, power line and sensor |
| Sensor | Pt100, EN60751 |
| Temperature range | 30°C … 200 °C (on request 250 °C) |
| Accuracy | +/- 0,5°C |
| Additional sensor | 1 x Thermo connector type K, EN 60584, for the surface temperature |
| Main switch | on the back side |
| Fuses | 2 pcs F3,15A L250 VAC |
+ Standards
ISO
8987
EN
8987
DIN
16 9168987
+ Resources
Features
- B-Timing Plate Design: The standard heating surface includes four specialized depressions to accept multiple samples simultaneously, with custom flat-plate versions available for specific application needs.
- Advanced Temperature Regulation: Equipped with the TCT-1 controller and a high-accuracy Pt100 sensor, maintaining a temperature range of 30°C to 200°C (expandable to 250°C) with ±0.5°C precision.
- Compliance with Standards: Specifically engineered to meet the testing requirements of DIN 16 916 and DIN EN ISO 8987, ensuring results are globally recognized for resin reactivity analysis.
- Dual-Sensor Monitoring: Features an additional Type K thermocouple connection dedicated to monitoring surface temperature, providing redundant verification of thermal stability during testing.
- Integrated Process Timer: The control unit houses a built-in digital stopwatch, allowing laboratory technicians to synchronize thermal application with precise time measurement for repeatable data collection.
Technical Specifications
B-Timing Plate
| Voltage | 115 VAC or 230 VAC, 50/60 Hz |
| Power | 160 W |
Temperature-Controller TCT-1 with Stopwatch
| Voltage | 100 …240 VAC, 50 / 60 Hz |
| Power | 200 VA with connected B-Timing plate |
| Connections | 8 Pol Binder plug, power line and sensor |
| Sensor | Pt100, EN60751 |
| Temperature range | 30°C … 200 °C (on request 250 °C) |
| Accuracy | +/- 0,5°C |
| Additional sensor | 1 x Thermo connector type K, EN 60584, for the surface temperature |
| Main switch | on the back side |
| Fuses | 2 pcs F3,15A L250 VAC |
Application & Standards
Accessories
Software
FAQs
Related Products