Thermal Abuse Test Chamber
Battery Cell Thermal Safety Testing
Battery Cell Thermal Safety Testing
Battery Cell Thermal Safety Testing
Model No. :
Model No. : BE-8103
Brand : DG Bell
This chamber is an all-in-one safety structure designed to assess the thermal integrity of single battery cells by precisely simulating thermal abuse conditions. It is engineered with a linear heating rate of 5°C/min to rapidly reach the maximum 150°C temperature, while incorporating essential safety features like an explosion-proof door lock, pressure relief device, and fire extinguishing system.
-
Maximum +150°C adjustable temperature
-
Linear heating rate 5°C/min to 150°C
-
Temperature control accuracy ±0.5°C
− Features
Relevant Standard Test Requirements
The heating test is carried out as follows:
- The single battery is charged according to the method of 6.1.
- Put the single battery into the temperature chamber.
- For lithium-ion batteries, the temperature chamber is increased from room temperature to 130 ° C ± 2 ° C at .
- A rate of 5 ° C / min, and the heating is stopped after maintaining the temperature for 30 minutes.
- For nickel metal cyanide batteries, the temperature chamber is raised from room temperature to 85 ° C ± 2 ° C
- At a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 2h.
- Observe for 1h.
Battery Module Safety Test
- The battery module battery shall be charged according to the method in 6.1.4.
- For lithium-ion batteries, the temperature chamber is raised from room temperature to 130 ° C ± 2 ° C
- At a Rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 30 minutes.
- For nickel metal cyanide batteries, the temperature chamber is raised to 85 ° C ± 2 ° C at room temperature.
- At a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 2h.
- Observe for 1h.
+ Technical Specifications
| Structure | All-in-one structure, the door uses explosion-proof lock + explosion-proof chain Normal temperature to 150°C (Adjustable) |
| Controlling Accuracy | ±0.5℃ |
| Temperature Deviation | ±2.0℃, No load |
| Heating Rate | RT~150°C (Linear 5°C/min) |
| Control Display | PLC touch type (7 inch) + remote control |
| Working Cabinet Dimension | W600XD500XH600 mm |
| External Dimension | W940XD780XH1620 mm |
| Inner Chamber Material | SUS304 Stainless steel with mirror-finish |
| External Chamber Material | SECC steel plate, fine powder paint coating (thickness 1.5mm) |
| Bottom | With universal wheel |
| Observation Window | 390 X 360mm (20mm thick explosion-proof glass, explosion-proof mesh) |
| Insulation Material | Imported high-density glass wool, good heat insulation, to ensure maximum temperature insulation, tight sealing materials for high temperature resistant silicone, withstanding high temperatures over 300 degrees for a long time |
| Terminal Hole | Diameter 50mm Terminal hole on the left and right sides |
| Power Supply | 220V / 50HZ / 4.0KW |
| USB Interface | With USB interface, the test data can be exported |
| Auxiliary Function | Explosion-proof pressure relief device, smoke exhaust device, explosion-proof lighting device, electronic door lock system, safety stop switch |
+ Standards
+ Resources
Features
Relevant Standard Test Requirements
The heating test is carried out as follows:
- The single battery is charged according to the method of 6.1.
- Put the single battery into the temperature chamber.
- For lithium-ion batteries, the temperature chamber is increased from room temperature to 130 ° C ± 2 ° C at .
- A rate of 5 ° C / min, and the heating is stopped after maintaining the temperature for 30 minutes.
- For nickel metal cyanide batteries, the temperature chamber is raised from room temperature to 85 ° C ± 2 ° C
- At a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 2h.
- Observe for 1h.
Battery Module Safety Test
- The battery module battery shall be charged according to the method in 6.1.4.
- For lithium-ion batteries, the temperature chamber is raised from room temperature to 130 ° C ± 2 ° C
- At a Rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 30 minutes.
- For nickel metal cyanide batteries, the temperature chamber is raised to 85 ° C ± 2 ° C at room temperature.
- At a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 2h.
- Observe for 1h.
Technical Specifications
| Structure | All-in-one structure, the door uses explosion-proof lock + explosion-proof chain Normal temperature to 150°C (Adjustable) |
| Controlling Accuracy | ±0.5℃ |
| Temperature Deviation | ±2.0℃, No load |
| Heating Rate | RT~150°C (Linear 5°C/min) |
| Control Display | PLC touch type (7 inch) + remote control |
| Working Cabinet Dimension | W600XD500XH600 mm |
| External Dimension | W940XD780XH1620 mm |
| Inner Chamber Material | SUS304 Stainless steel with mirror-finish |
| External Chamber Material | SECC steel plate, fine powder paint coating (thickness 1.5mm) |
| Bottom | With universal wheel |
| Observation Window | 390 X 360mm (20mm thick explosion-proof glass, explosion-proof mesh) |
| Insulation Material | Imported high-density glass wool, good heat insulation, to ensure maximum temperature insulation, tight sealing materials for high temperature resistant silicone, withstanding high temperatures over 300 degrees for a long time |
| Terminal Hole | Diameter 50mm Terminal hole on the left and right sides |
| Power Supply | 220V / 50HZ / 4.0KW |
| USB Interface | With USB interface, the test data can be exported |
| Auxiliary Function | Explosion-proof pressure relief device, smoke exhaust device, explosion-proof lighting device, electronic door lock system, safety stop switch |
Application & Standards
Accessories
Software
FAQs